TOKYO KEIKI ULTRASONIC FLOWMETER UFW-100

TOKYO KEIKI ULTRASONIC FLOWMETER UFW-100


Specifications
Ultrasonic Flowmeter UFW-100
Specifications Measurement Method Ultrasonic pulse transit time difference method Diameter Range DN 25mm - 600mm Accuracy Pipe Diameter Velocity 1m/s Velocity < 1m/s DN 25mm - 40mm (*1) ±2.5% R.D. ±0.025m/s DN 50mm - 90mm ±2.0% R.D. ±0.020m/s DN 100mm - 250mm ±1.5% R.D. ±0.015m/s DN 300mm - 600mm ±1.0% R.D. ±0.010m/s Output Analog output 1port(Std.) 4-20mA Allowable load resistance 600Ω Max. Relay output 1port(Std.) for Totalizing, Warning or Directional output Digital output 1port(Std.) USB connection / Inter-communication mode 1port(Option) RS-485 / MODBUS-RTU output Input Analog Input 1port(Option) 4-20 mA / Passive input Main unit Protection Degree IEC60529 IP65 Transducer Applicable Temperature 20 ~ 60℃ Protection Degree IEC60529 IP65(Std.) / IEC60529 IP67(Option) Cable Length 30m Max. (Applicable cable model : RG-223U) Data Logging Over 68,000 lines(exp. more than 1month by 1min interval / Interval selectable) Logged Item; Date, time, Instantaneous flow rate, +Total, -Total, Error code and Event status Function PC Graphical parameter setting 4 key configurable from the console Self-diagnostics Disturbance detection No Echo receiving warning Low flow cut Zero shift Span compensation Fixed Analog Output Auto Gain Control Preset Totalize Start Data Retention Echo-wave form monitor Error Status indication
SKU
UFW-100
Details

Ultrasonic Flowmeter UFW-100 Now Comes, Measurement Unlimited by the Imagination.

TOKYO KEIKI, the world’s first supplier of ultrasonic flowmeters and industry pioneer is proud to introduce the clamp-on flowmeters of next generation which are environmentally friendly and provide the consistent reliability and “Made in Japan”quality that customers have come to expect from the TOKYO KEIKI brand.
The new UFW-100 Series ultrasonic flowmeter boasts a smaller, more compact footprint & size and lower power consumption in a material-saving, RoHS compliant design.

<Advantage of "Clamp-On"> 
No Pressure Loss (pump power savings)
No Wetted Parts (no contact with liquid)
No Moving Parts (no wear)
No Need to Stop the Process (easy installation)

<Typical Application> 
Water Distribution
Factory Utilities
HVAC Systems
Process Monitoring
Replacement for old in-line meters
Desalination Processes

<Main Functions and Features> 
Measuring Accuracy : +/- 1.0~2.5% of reading
4-20mA Output (1ch)
Contact Output (1ch)
Data Logging (1min. intervals; up to 1month)
RS-485 Modbus Output (1ch) (Option)
Analog Current Input (1ch) (Option)
Smaller, Compact Footprint & Size*1
Lower Power Consumption *2
RoHS Compliant

View more about TOKYO KEIKI ULTRASONIC FLOWMETER UFW-100 on main site