PULSAR MEASUREMENT IMP LITE

PULSAR MEASUREMENT IMP LITE

Category: SENSOR

Specifications
IMP LITE
.
Details

IMP Lite

The IMP Lite is part of the IMP non-contacting level sensor range from Pulsar Measurement. It is a lower-cost alternative to the IMP level sensor and is designed to be used wherever you need a reliable, non-contacting indication of level measurement. The IMP Lite is compact and low-profile, when used on battery power for intermittent applications, its high-speed boot up of circa 3 second maximizes battery life. 

All IMP level sensors from Pulsar Measurement feature unique digital echo processing software and onboard keypads and displays, giving an instant, accurate, and reliable level measurement reading. The units include an analog output to provide simple and easy integration with existing site control systems to drive a display. 

IMP non-contacting level sensors are suitable for tank level measurement, water and wastewater applications, stock control, tank volume conversions, industrial level measurement, and many more! 

Features 

  • Compact, self-contained level measurement
  • 2-wire configuration
  • RJ11 port
  • Up to 10 m (32.8 ft) range available

Technical Specifications 

General Specifications
Spec: Description:
Dimensions 175 mm (6.9 in) H x 130 mm (5.1 in) D
Cable entry 2 x 16 mm (0.6 in) cable glands, 3.5 mm to 10 mm (0.1 in to 0.4 in) cable diameter
Mounting IMP3 - 3 m (9.8 ft) version: 1.5 in BSP/NPT
IMP 6 - 6 m (19.7 ft) version: 1.5 in BSP/NPT
IMP10 - 10 m (32.8 ft) version: 2 in BSP/NPT
Suits BSP & NPT, parallel and tapered
Weight Approximately 1 kg (2.2 lbs)
Temperature (Process) -40 °C to 80 °C (-40 °F to 176 °F)
Temperature (Ambient) -20 °C to 65 °C (-4 °F to 149 °F)
Input Voltage 11-30 V, 3.5-22 mA
Accuracy ±0.25% or 6 mm (0.2 in); whichever is greater
Resolution ±0.1% or 2 mm (0.1 in); whichever is greater

 


View more about PULSAR MEASUREMENT IMP LITE on main site